************************************************* Uploading new files to the flight instrument: Build and load the FTS_V04.l updated with the 2032 FTS id. Load the following scripts: H_9020 Initiate the mod-L sequence (FTS=1022) and the twice daily calibrations (FTS=2032). H_2721 Observation mode PZT flat H_2722 Calibration mode PZT flat H_2723 Detune framelist H_2724 Reduced focus sweep H_2725 Full focus sweep H_2731 Obs and cal mode PZT flats, reduced focus sweep H_2732 Obs and cal mode PZT flats, reduced focus sweep, detune H_2733 Obs and cal mode PZT flats, full focus sweep H_2734 Obs and cal mode PZT flats, full focus sweep, detune H_6020 PZT offsets for obs mode PZT flat H_6022 PZT offsets for cal mode PZT flat ************************************************* Test procedure Initiate script H_9020.scr to start the mod-L sequence at 17:50 UT. Verify that FTS=1022 is running and cadence = 90 Verify the FTS entries are correct: FTS_ID=1022 PRIORITY=7 FTS_ID=2032 PRIORITY=5 At 18:00 UT, verify that the daily calibrations (FTS=2032) runs properly After the daily calibration FTS runs, proceed with the following tests Initiate the following scripts: H_2724 Reduced focus sweep Verify that FTS 3040 runs H_2725 Full focus sweep Verify that FTS 3043 runs H_2721 Observation mode PZT flat Verify that FTS 3041 runs and script H_6020 is started H_2722 Calibration mode PZT flat Verify that FTS 3042 runs and script H_6022 is started The following should be run at about the velocity zero crossing The standard detune is scheduled for 04-Nov-2015 @ 18:46 UT H_2723 Detune framelist Verify that FTS 3027 runs and that cadence changes to 135 Verify that the cadence returns to 90 at the completion of this script H_2731 Obs and cal mode PZT flats, reduced focus sweep Verify that FTS 3041 runs and script H_6020 is started Verify that FTS 3042 runs and script H_6022 is started Verify that FTS 3040 runs H_2733 Obs and cal mode PZT flats, full focus sweep Verify that FTS 3041 runs and script H_6020 is started Verify that FTS 3042 runs and script H_6022 is started Verify that FTS 3043 runs Initiate script H_9060.scr to return to the normal observing program Verify that FTS=1021 is running and cadence = 135 Verify the FTS entries are correct: FTS_ID=1021 PRIORITY=7 FTS_ID=2021 PRIORITY=5 ************************************************* The following scripts will be run at a later time after the detune script has been verified to function correctly: H_2732 Obs and cal mode PZT flats, reduced focus sweep, detune H_2734 Obs and cal mode PZT flats, full focus sweep, detune