#! $Id: H_6002.scr,v 1.8 2010/12/14 02:29:13 allard Exp $ #! $Name: $ #! Description: PZT flat with PZT voltage commanding. Calmode version. #! Group: MACRO # $Log: H_6002.scr,v $ # Revision 1.8 2010/12/14 02:29:13 allard # *** empty log message *** # # Revision 1.6 2010/12/14 01:46:32 elehman # Updated FTS values for retune # # Revision 1.5 2010/04/30 21:20:45 schou # Changed FTS ID of script # # Revision 1.4 2010/04/23 05:07:49 schou # Added multiple loop openings # # Revision 1.3 2010/04/20 15:30:24 schou # Back to using odd frames. Wait 500ms extra before opening loop. # # Revision 1.2 2010/04/20 06:12:40 schou # Move steps one early # # Revision 1.1 2010/04/20 04:15:56 schou # Initial checkin # # # Wait for proper FTS to start /INT_SS_TEST TELEMETRY=HMI_SEQ_FTS_ID_ACTIVE VALUE=3022 RETRY=60 /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=1 retry=60 /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open # Auto generated from here /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=3 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-20 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-17 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-9 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=5 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-22 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-10 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-15 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=7 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-8 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-10 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-21 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=9 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-2 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-30 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-13 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=11 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-29 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-35 /HMI_IS_PZT_OFFSET PZT=C OFFSET=6 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=13 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-46 /HMI_IS_PZT_OFFSET PZT=B OFFSET=14 /HMI_IS_PZT_OFFSET PZT=C OFFSET=1 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=15 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-6 /HMI_IS_PZT_OFFSET PZT=B OFFSET=30 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-59 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=17 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=44 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-73 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=19 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=C OFFSET=47 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=21 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=B OFFSET=44 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-73 # Auto generated to here /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=23 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-16 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-16 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-13 /hmi_is_control loop=closed