#! $Id: H_6022.scr,v 1.2 2015/11/04 23:09:04 elehman Exp $ #! $Name: $ #! Description: PZT flat with PZT voltage commanding. Calmode version. #! Group: MACRO # # Wait for proper FTS to start /INT_SS_TEST TELEMETRY=HMI_SEQ_FTS_ID_ACTIVE VALUE=3042 RETRY=60 /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=1 retry=60 /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open /int_ss_wait MILLISECONDS=500 /hmi_is_control loop=open # Auto generated from here /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=3 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-20 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-17 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-9 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=5 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-22 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-10 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-15 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=7 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-8 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-10 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-21 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=9 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-2 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-30 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-13 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=11 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-29 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-35 /HMI_IS_PZT_OFFSET PZT=C OFFSET=6 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=13 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-46 /HMI_IS_PZT_OFFSET PZT=B OFFSET=14 /HMI_IS_PZT_OFFSET PZT=C OFFSET=1 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=15 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-6 /HMI_IS_PZT_OFFSET PZT=B OFFSET=30 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-59 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=17 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=44 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-73 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=19 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=C OFFSET=47 # /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=21 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-76 /HMI_IS_PZT_OFFSET PZT=B OFFSET=44 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-73 # Auto generated to here /int_ss_test TELEMETRY=HMI_SEQ_FRLIST_POS VALUE=23 retry=60 /int_ss_wait MILLISECONDS=1000 /HMI_IS_PZT_OFFSET PZT=A OFFSET=-16 /HMI_IS_PZT_OFFSET PZT=B OFFSET=-16 /HMI_IS_PZT_OFFSET PZT=C OFFSET=-13 /hmi_is_control loop=closed