Level-1.5 (Observables) Quality Flag Quality Bit Documentation

NB: UPDATED TO MATCH http://jsoc.stanford.edu/doc/data/hmi/Quality_Bits/QUALITY.txt version of 24 May 2013

Current meaning of the QUALITY keyword for the line-of-sight observables

QUALITY

NO OBSERVABLES PRODUCED AND THE REASON WHY

QUAL_NODATA

(0x80000000)

no l.o.s. observables image was produced (empty record created, with NO DATA SEGMENT. Most keywords have default value)

QUAL_TARGETFILTERGRAMMISSING

(0x40000000)

no target filtergram was found near target time (target filtergram=filtergram used to identify the framelist): due either to missing filtergrams or because no observable sequence was run

QUAL_NOINTERPOLATEDKEYWORDS

(0x20000000)

could not interpolate some keywords at target time (CROTA2, DSUN_OBS, and CRLT_OBS are required by do_interpolate()), because several lev 1 records are missing/corrupted

QUAL_NOFRAMELISTINFO

(0x10000000)

could not figure out which observables framelist was used, or the framelist run for the required time range is not an observables framelist

QUAL_WRONGCADENCE

(0x08000000)

the cadence corresponding to the framelist run at the required time does not match the expected value provided by user (error from user, or issue with the framelist)

QUAL_WRONGTARGET

(0x04000000)

the target filtergram does not belong to the current framelist (something is wrong either with the framelist or the target filtergram)

QUAL_MISSINGLEV1D

(0x02000000)

not enough lev1d filtergrams to produce an observable (too many lev 1 records were missing or corrupted)

QUAL_MISSINGKEYWORDLEV1D

(0x01000000)

could not read some needed keywords (like FID) in the lev1d data (too many lev 1 records were missing or corrupted and the corresponding lev 1d record is unusable)

QUAL_WRONGWAVELENGTHNUM

(0x00800000)

the number of wavelengths in the lev1d records is not correct (issue with the framelist, or too many lev 1 records were missing or corrupted)

QUAL_MISSINGKEYWORDLEV1P

(0x00400000)

could not read some needed keywords in the lev1p data (too many lev 1 records were missing or corrupted and the corresponding lev 1p record is unusable)

QUAL_NOLOOKUPRECORD

(0x00200000)

could not find a record for the look-up tables for the MDI-like algorithm (the MDI-like algorithm could not be applied)

QUAL_NOLOOKUPKEYWORD

(0x00100000)

could not read the keywords of the look-up tables for the MDI-like algorithm (the MDI-like algorithm could not be applied)

QUAL_NOTENOUGHINTERPOLANTS

(0x00080000)

not enough interpolation points for the temporal interpolation at a given wavelength and polarization (too many lev 1 records were missing or corrupted)

QUAL_INTERPOLATIONFAILED

(0x00040000)

the temporal interpolation routine failed (no lev1d record was produced)

QUAL_MISSINGLEV1P

(0x00020000)

not enough lev1p records to produce an observable (too many lev 1 records were missing or corrupted)

QUAL_NOCOEFFKEYWORD

(0x00000200)

could not read the keywords of the polynomial coefficient series for the correction of the MDI-like algorithm

QUAL_NOCOEFFPRECORD

(0x00000080)

could not find a record for the polynomial coefficient for the correction of the MDI-like algorithm, or could not access the keywords of a specific record

OBSERVABLES CREATED BUT IN SUB-OPTIMAL CONDITIONS

QUAL_LOWINTERPNUM

(0x00010000)

the number of interpolation points (for temporal interpolation) was not always as high as expected, AND/OR 2 interpolation points were separated by more than the cadence

QUAL_LOWKEYWORDNUM

(0x00008000)

some keywords (especially CROTA2, DSUN_OBS, and CRLT_OBS) could not be interpolated properly at target time, but a closest-neighbour approximation was used

QUAL_ISSTARGET

(0x00004000)

the ISS loop was OPEN for one or several filtergrams used to produce the observable

QUAL_NOTEMP

(0x00002000)

cannot read the temperatures needed for polarization calibration (default temperature used)

QUAL_NOGAPFILL

(0x00001000)

the code could not properly gap-fill all the lev 1 filtergrams

QUAL_LIMBFITISSUE

(0x00000800)

some lev1 records were discarded because R_SUN, and/or CRPIX1/CRPIX2 were missing or were too different from the median value of the other lev1 records (too much jitter for instance)

QUAL_NOCOSMICRAY

(0x00000400)

some cosmic-ray hit lists could not be read for the level 1 filtergrams

QUAL_ECLIPSE

(0x00000100)

at least one lev1 record was taken during an eclipse

QUAL_LARGEFTSID

(0x00000040)

HFTSACID of target filtergram > 4000, which adds noise to observables

QUAL_POORQUALITY

(0x00000020)

poor quality: careful when using these observables due to eclipse, or lunar transit, or thermal recovery, or open ISS, or other issues...

Current meaning of the QUALITY keyword for the 12-min averaged IQUV

SOME (OR ALL) IQUV DATA SEGMENTS WERE NOT PRODUCED AND THE REASON WHY

QUAL_NODATA

(0x80000000)

not all the IQUV images were produced (SOME OR ALL DATA SEGMENTS ARE MISSING)

QUAL_TARGETFILTERGRAMMISSING

(0x40000000)

no target filtergram was found near target time (target filtergram=filtergram used to identify the framelist): due either to missing filtergrams or because no observable sequence was run

QUAL_NOINTERPOLATEDKEYWORDS

(0x20000000)

could not interpolate some keywords at target time (CROTA2, DSUN_OBS, and CRLT_OBS are required by do_interpolate()), because several level 1 records are missing/corrupted

QUAL_NOFRAMELISTINFO

(0x10000000)

could not figure out which observables framelist was used, or the framelist run for the required dates is not an observables framelist

QUAL_WRONGCADENCE

(0x08000000)

the cadence corresponding to the framelist run at required times does not match the expected value provided by user (error from user, or issue with the framelist)

QUAL_WRONGFRAMELISTSIZE

(0x04000000)

the current framelist size does not match the value from the command line

QUAL_WRONGNPOL

(0x02000000)

the current framelist npol does not match the value from the command line

QUAL_WRONGPOLTYPE

(0x01000000)

the current framelist does not allow for the production of I,Q,U, and V data

QUAL_WRONGTARGET

(0x00800000)

the target filtergram does not belong to the current framelist (something is wrong either with the framelist or with the target filtergram)

QUAL_ERRORFRAMELIST

(0x00400000)

the filtergrams are not where they should be in the framelist (issue with the framelist)

QUAL_WRONGWAVELENGTHNUM

(0x00200000)

the number of wavelengths in the lev1d records is not correct (issue with the framelist, or too many lev 1 records were missing or corrupted)

QUAL_NOLOOKUPRECORD

(0x00100000)

could not find a record for the look-up tables for the MDI-like algorithm (the MDI-like algorithm could not be used). NB: THIS BIT IS CURRENTLY NOT USED BUT SHOULD BE IN THE NEAR FUTURE

QUAL_NOLOOKUPKEYWORD

(0x00080000)

could not read the keywords of the look-up tables for the MDI-like algorithm (the MDI-like algorithm could not be used). NB: THIS BIT IS CURRENTLY NOT USED BUT SHOULD BE IN THE NEAR FUTURE

QUAL_NOTENOUGHINTERPOLANTS

(0x00040000)

not enough interpolation points for the temporal interpolation at a given wavelength and polarization (too many lev 1 records were missing or corrupted)

QUAL_INTERPOLATIONFAILED

(0x00020000)

the temporal interpolation routine failed

OBSERVABLES CREATED BUT IN SUB-OPTIMAL CONDITIONS

QUAL_LOWINTERPNUM

(0x00010000)

the number of averaging points is lower than TempIntNum, AND/OR 2 interpolation points were separated by more than the cadence

QUAL_LOWKEYWORDNUM

(0x00008000)

some keywords (especially CROTA2, DSUN_OBS, and CRLT_OBS) could not be interpolated properly at target time, but a closest-neighbour approximation was used

QUAL_ISSTARGET

(0x00004000)

the ISS loop was OPEN for one or several filtergrams used to produce the observable

QUAL_NOTEMP

(0x00002000)

cannot read the temperatures needed for polarization calibration (default temperature used)

QUAL_NOGAPFILL

(0x00001000)

the code could not properly gap-fill all the lev 1 filtergrams

QUAL_LIMBFITISSUE

(0x00000800)

some lev1 records were discarded because R_SUN, and/or CRPIX1/CRPIX2 were missing or too different from the median value of the other lev 1 records (too much jitter for instance)

QUAL_NOCOSMICRAY

(0x00000400)

some cosmic-ray hit lists could not be read for the level 1 filtergrams

QUAL_ECLIPSE

(0x00000200)

at least one lev1 record was taken during an eclipse

QUAL_LARGEFTSID

(0x00000100)

HFTSACID of target filtergram > 4000, which adds noise to observables

QUAL_TEMPERROR

(0x00000080)

Code error discovered that will be corrected in later processing versions, see notes at http://jsoc2.stanford.edu/doc/data/hmi/Quality_Bits

QUAL_POORQUALITY

(0x00000020)

poor quality: careful when using these observables due to eclipse, or lunar transit, or thermal recovery, or open ISS, or other issues...

JsocWiki: Lev1qualBits (last edited 2019-04-06 04:12:16 by ArtAmezcua)