HMI Pipeline Module - TimeAverage_IQUV
For a given time and duration this pipeline module locates the corrected level 1 HMI filtergrams needed to compute I, Q, U, and V. The filtergrams are interpolated to the proper time, remapped to the correct disk coordinates, and averaged to determine I,Q,U,& V. The output is a DRMS dataset containing the appropriately time-averaged quantities corrected for solar rotation and other known instrumental effects.
Module Inputs
- Input is the set of corrected level 1.0 HMI filtergrams needed to compute I, Q, U, and V for a specified time period.
Module Outputs
- The output is a DRMS dataset containing the appropriately time-averaged quantities I, Q, U,and V, corrected for solar rotation and other known instrumental effects.
Cadence
- Nominally 12 minute averages of I,Q,U, and V will be produced.
- Effectively 8 90-second input records will be averaged, but actually more will contribute with appropriate weighting to reduce aliasing.
Options
- Anti-aliasing option
- Time and duration of averaging
Archive
- I,Q,U, and V are not archived.
Overall Status of Module
- 75% complete
Status of Code
- 85%
- Code has been run on HMI test data
Status of DRMS module
- 50%
Issues needing resolution
- Type of temporal anti-alias temporal filtering
Responsible scientist
- Jesper Schou
Remarks
Back to HMIModuleTable
Back to Lev1Doc
Back to VectorMagneticField
Back to FrontPage