Line 1: | Line 1: |
== HMI Pipeline Module - TimeAveraged_IQUV == | == HMI Pipeline Module - TimeAverage_IQUV == |
Line 5: | Line 5: |
Line 8: | Line 7: |
The nominal cadence is 12 minutes, nominally averaging 8 90-second input records, but actually more with appropriate weighting to reduce aliasing. | |
Line 10: | Line 8: |
Output data are temporary products and not archived. | ===== Module Inputs ===== . Input is the set of corrected level 1.0 HMI filtergrams needed to compute I, Q, U, and V for a specified time period. |
Line 12: | Line 11: |
Currently this module has not been prototyped. | ===== Module Outputs ===== . The output is a DRMS dataset containing the appropriately time-averaged quantities I, Q, U,and V, corrected for solar rotation and other known instrumental effects. |
Line 14: | Line 14: |
Currently this code has not been written. | |
Line 16: | Line 15: |
Currently this module has not been tested. | ===== Cadence ===== . Nominally 12 minute averages of I,Q,U, and V will be produced. . Effectively 8 90-second input records will be averaged, but actually more will contribute with appropriate weighting to reduce aliasing. ===== Options ===== . Anti-aliasing option . Time and duration of averaging |
Line 18: | Line 23: |
Currently this module has known issues: * type of temporal anti-alias filtering |
===== Archive ===== . I,Q,U, and V are not archived. |
Line 21: | Line 26: |
The responsible scientist is Jesper Schou | ===== Overall Status of Module ===== . 75% complete |
Line 23: | Line 29: |
--- . ''Back to ["HMIModuleTable"]'' |
===== Status of Code ===== . 85% . Code has been run on HMI test data ===== Status of DRMS module ===== . 50% ===== Issues needing resolution ===== * Type of temporal anti-alias temporal filtering ===== Responsible scientist ===== . Jesper Schou ===== Remarks ===== ---- . ''Back to [[HMIModuleTable]]'' |
HMI Pipeline Module - TimeAverage_IQUV
For a given time and duration this pipeline module locates the corrected level 1 HMI filtergrams needed to compute I, Q, U, and V. The filtergrams are interpolated to the proper time, remapped to the correct disk coordinates, and averaged to determine I,Q,U,& V. The output is a DRMS dataset containing the appropriately time-averaged quantities corrected for solar rotation and other known instrumental effects.
Module Inputs
- Input is the set of corrected level 1.0 HMI filtergrams needed to compute I, Q, U, and V for a specified time period.
Module Outputs
- The output is a DRMS dataset containing the appropriately time-averaged quantities I, Q, U,and V, corrected for solar rotation and other known instrumental effects.
Cadence
- Nominally 12 minute averages of I,Q,U, and V will be produced.
- Effectively 8 90-second input records will be averaged, but actually more will contribute with appropriate weighting to reduce aliasing.
Options
- Anti-aliasing option
- Time and duration of averaging
Archive
- I,Q,U, and V are not archived.
Overall Status of Module
- 75% complete
Status of Code
- 85%
- Code has been run on HMI test data
Status of DRMS module
- 50%
Issues needing resolution
- Type of temporal anti-alias temporal filtering
Responsible scientist
- Jesper Schou
Remarks